Perkins diesel generators in the UAE, 9.9–2,500 kVA

42 Perkins-engined diesel generator models from 9.9 to 2,500 kVA standby, with a Leroy-Somer or Stamford alternator and a Deep Sea controller. Open or in a silent canopy, each with its own datasheet and a same-day price.

Models
42
Standby
9.9–2,500 kVA
Prime
9–2,250 kVA
Warranty
12 months / 1,000 h

All Perkins generator models (42)

Open any model to download its datasheet or request a price.

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-P99.99Perkins 403A-11G13Datasheet
4U-P131413Perkins 403A(D)-15G13.7Datasheet
4U-P1516.515Perkins 403A-15G23.7Datasheet
4U-P202220Perkins 404A(D)-22G15.3Datasheet
4U-P242724Perkins 404D-22G—Datasheet
4U-P303330Perkins 1103A-33G7.2Datasheet
4U-P455045Perkins 1103A-33TG110.8Datasheet
4U-P606660Perkins 1103A-33TG214Datasheet
4U-P808880Perkins 1104A-44TG214Datasheet
4U-P100110100Perkins 1104C-44TAG222.6Datasheet
4U-P135150135Perkins 1106A-70TG130.2Datasheet
4U-P150165150Perkins 1106A-70TAG233Datasheet
4U-P180200180Perkins 1106A-70TAG341.6Datasheet
4U-P200220200Perkins 1106A-70TAG445.8Datasheet
4U-P200C220200Perkins 1506A-E88TAG154.5Datasheet
4U-P200B225200Perkins 1206A-E70TAG154.5Datasheet
4U-P225250225Perkins 1206A-E70TTAG248.6Datasheet
4U-P230250230Perkins 1506A-E88TAG254.5Datasheet
4U-P250275250Perkins 1206A-E70TTAG356.9Datasheet
4U-P250B275250Perkins 1506A-E88TAG356.9Datasheet
4U-P275300275Perkins 1506A-E88TAG465Datasheet
4U-P300330300Perkins 1506A-E88TAG565Datasheet
4U-P300B330300Perkins 1706A-E93TAG165Datasheet
4U-P352388352Perkins 1706A-E93TAG277Datasheet
4U-P350400350Perkins 2206A-E13TAG277Datasheet
4U-P400450400Perkins 2206A-E13TAG393Datasheet
4U-P455500455Perkins 2506A-E15TAG199Datasheet
4U-P500550500Perkins 2506A-E15TAG2106Datasheet
4U-P600660600Perkins 2806A-E18TAG1A129Datasheet
4U-P650700650Perkins 2806A-E18TAG2132Datasheet
4U-P660730660Perkins 2806A-E18TTAG4132Datasheet
4U-P746820746Perkins 4006-23TAG2A157Datasheet
4U-P770850770Perkins 2806A-E18TTAG5157Datasheet
4U-P800900800Perkins 4006-23TAG3A172Datasheet
4U-P9001,000900Perkins 4008-TAG1195Datasheet
4U-P10001,1001,000Perkins 4008-TAG2—Datasheet
4U-P12501,3751,250Perkins 4012-46TWG2A266Datasheet
4U-P15001,6501,500Perkins 4012-46TAG2A310Datasheet
4U-P17101,8751,710Perkins 4012-46TAG3A—Datasheet
4U-P18502,0001,850Perkins 4016-61TRG1383Datasheet
4U-P20002,2502,000Perkins 4016-61TRG2434Datasheet
4U-P22502,5002,250Perkins 4016-61TRG3470Datasheet

Ratings to ISO 8528 at 50 Hz, 1500 rpm.

What comes with every Perkins set

Straight from the datasheets. For one model in detail open its page from the table above, or build it in 3D.

Engine
Perkins 403A-11G1 … 4016-61TRG3
Alternator
4U · Leroy-Somer | Stamford
Controller
Deep Sea DSE4520 MKII / DSE6110 MKII
Enclosure
Open skid or silent canopy, or container
Frequency
50 Hz · 1500 rpm
Warranty
12 months / 1,000 running hours

Perkins generator ranges

  • Perkins Diesel Generator 10–200 kVA
    Generators10–200 kVA

    Perkins Diesel Generator 10–200 kVA

    Engine
    Perkins
    Fuel
    Diesel

    1-year warranty

    Compact Perkins 400 and 1100 Series powered generator sets for villas, shops, telecom sites and light commercial standby. Low fuel consumption, wide parts availability across the GCC and fast delivery from our SAIF Zone warehouse.

  • Perkins Industrial Generator 250–2500 kVA
    Generators250–2,500 kVA

    Perkins Industrial Generator 250–2500 kVA

    Engine
    Perkins
    Fuel
    Diesel

    1-year warranty

    Heavy-duty Perkins 1300, 2000 and 4000 Series sets for factories, hospitals, data rooms and towers. Supplied as containerised or canopy units, ready for synchronisation and remote monitoring.

Perkins generator questions

42 models from 9.9 to 2,500 kVA standby: 9.9, 14, 16.5, 22, 27, 33, 50, 66, 88, 110, 150, 165, 200, 220, 225, 250, 275, 300, 330, 388, 400, 450, 500, 550, 660, 700, 730, 820, 850, 900, 1,000, 1,100, 1,375, 1,650, 1,875, 2,000, 2,250, 2,500 kVA. Each model has its own datasheet with the engine, alternator, fuel consumption and dimensions.

It depends on the rating and the load. From the datasheets: 4U-P9 (9.9 kVA) uses about 2.3 L/h at 75% and 3 L/h at 100% prime load; 4U-P455 (500 kVA) uses about 73 L/h at 75% and 99 L/h at 100% prime load; 4U-P2250 (2,500 kVA) uses about 344 L/h at 75% and 470 L/h at 100% prime load. Every model page lists its own figures.

Standby is the rating for mains-failure use; prime is the rating for continuous running with a varying load (ISO 8528). For example, the 4U-P100 is 110 kVA standby and 100 kVA prime. Size on prime if the generator is your main source of power.

Alternator: 4U · Leroy-Somer | Stamford. Controller: Deep Sea DSE4520 MKII / DSE6110 MKII, depending on the model. The exact frame and controller for each rating are on its datasheet.

12 months / 1,000 running hours from 4U Power Generation, with service contracts available after handover.

Need a generator price today?