Skip to content
4U PowerGenerationFZC

9 models · 50 Hz

Kubota diesel generators in the UAE, 10–40 kVA

9 Kubota-engined diesel generator models from 10 to 40 kVA standby, with a Leroy-Somer or Stamford alternator and a Deep Sea controller. Open or in a silent canopy, each with its own datasheet and a same-day price.

Models
9
Standby
10–40 kVA
Prime
9–36 kVA
Warranty
12 months / 1,000 h

Kubota generators by size

All Kubota generator models (9)

Open any model to download its datasheet or request a price. A letter suffix (A/B/C) marks an alternative engine at the same rating.

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-K9109Kubota D1105-E2-BG2.5Datasheet
4U-K121312Kubota V1505-E2-BG3.2Datasheet
4U-K12.51412.5Kubota D1703-E2-BG23.5Datasheet
4U-K1415.414Kubota D1703-E2-BG—Datasheet
4U-K202220Kubota V2203-E2-BG4.7Datasheet
4U-K20C2220Kubota V2403-M-DI-BG—Datasheet
4U-K22.52522.5Kubota V2003-T-E2-BG5.6Datasheet
4U-K303330Kubota V3300-E2-BG27.2Datasheet
4U-K364036Kubota V3300-T-E2-BG8.6Datasheet

Ratings to ISO 8528 at 50 Hz, 1500 rpm.

What comes with every Kubota set

Straight from the datasheets. For one model in detail open its page from the table above, or build it in 3D.

Engine
Kubota D1105-E2-BG … V3300-T-E2-BG
Alternator
4U · Leroy-Somer | Stamford
Controller
Deep Sea DSE4520 MKII
Enclosure
Open skid or silent canopy
Frequency
50 Hz · 1500 rpm
Warranty
12 months / 1,000 running hours

Kubota generator ranges

  • Kubota Silent Generator 10–40 kVA
    Generators10–40 kVA

    Kubota Silent Generator 10–40 kVA

    Engine
    Kubota
    Fuel
    Diesel

    1-year warranty

    Ultra-quiet Kubota-powered sets for villas, clinics, retail units and events where noise matters. Compact footprint, single or three-phase output.

Kubota generator questions

9 models from 10 to 40 kVA standby: 10, 13, 14, 15.4, 22, 25, 33, 40 kVA. Each model has its own datasheet with the engine, alternator, fuel consumption and dimensions.

It depends on the rating and the load. From the datasheets: 4U-K9 (10 kVA) uses about 1.8 L/h at 75% and 2.5 L/h at 100% prime load; 4U-K36 (40 kVA) uses about 6.5 L/h at 75% and 8.6 L/h at 100% prime load. Every model page lists its own figures.

Standby is the rating for mains-failure use; prime is the rating for continuous running with a varying load (ISO 8528). For example, the 4U-K9 is 10 kVA standby and 9 kVA prime. Size on prime if the generator is your main source of power.

Alternator: 4U · Leroy-Somer | Stamford. Controller: Deep Sea DSE4520 MKII, depending on the model. The exact frame and controller for each rating are on its datasheet.

12 months / 1,000 running hours from 4U Power Generation, with service contracts available after handover.

Need a generator price today?

Send the kVA or your load list on WhatsApp — a sales engineer replies with options and pricing, usually within the hour.

CallWhatsApp