Skip to content
4U PowerGenerationFZC

Perkins generating set · 50 Hz

4U-P1850 — 1,850 kVA prime / 2,000 kVA standby Perkins diesel generator

1850 kVA prime / 2000 kVA standby, powered by a Perkins 4016-61TRG1 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy or container, with delivery, installation and commissioning across the UAE.

  • 1850 kVA prime
  • 2000 kVA standby
  • Perkins 4016-61TRG1
  • 1-year warranty
4U-P1850 — 1,850 kVA prime / 2,000 kVA standby Perkins diesel generator

Output ratings

Output ratings — 4U-P1850
Standby (ESP)2,000 kVA / 1,600 kW
Prime (PRP)1,850 kVA / 1,480 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-P1850
Make / modelPerkins 4016-61TRG1
Cylinders16 in 60° V
Displacement61.1 L
Bore × stroke160 × 190 mm
AspirationTurbocharged, water charge cooled
GoverningElectronic
CoolingWater cooled, radiator for 50 °C ambient
Coolant capacity210 L
Lube oil capacity214 L

Alternator

Alternator — 4U-P1850
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameLSA 52.3 S5
Stamford frameS7L1D-F41
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-P1850
50 % prime load155 L/h
75 % prime load277 L/h
100 % prime load383 L/h
Standby rating424 L/h

Dimensions & weight

Dimensions & weight — 4U-P1850
Open set (L × W × H)6050 × 2850 × 3700 mm
Open set weight14,500 kg
Container12 m custom container
Containerised weight19,870 kg
Base fuel tankExternal day tank (sized to site)
Noise @ 7 m88 dB(A) ± 3

Control & protection

Control & protection — 4U-P1850
ControllerDeep Sea DSE6110 MKII — auto start / AMF
Main breaker3-pole LS MCCB
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-P15001,6501,500Perkins 4012-46TAG2A310Datasheet
4U-P17101,8751,710Perkins 4012-46TAG3A—Datasheet
4U-P18502,0001,850Perkins 4016-61TRG1383Datasheet
4U-P20002,2502,000Perkins 4016-61TRG2434Datasheet
4U-P22502,5002,250Perkins 4016-61TRG3470Datasheet
All 42 Perkins models →