Lister Petter Generator 7–60 kVA
- Engine
- Lister Petter
- Fuel
- Diesel
1-year warranty
Compact Lister Petter-powered sets built for long, low-maintenance running — a proven choice for farms, telecom sites, workshops and remote cabins.

GenerationFZCPower solutions
for a reliable tomorrow
39 models · 50 Hz
39 Lister Petter-engined diesel generator models from 11 to 1,095 kVA standby, with a Leroy-Somer or Stamford alternator and a Deep Sea controller. Open or in a silent canopy, each with its own datasheet and a same-day price.
Open any model to download its datasheet or request a price. A letter suffix (A/B/C) marks an alternative engine at the same rating.
| Model | Standby kVA | Prime kVA | Engine | Fuel 100% (L/h) | Datasheet |
|---|---|---|---|---|---|
| 4U-L10 | 11 | 10 | Lister Petter SA315G2 | 2.9 | Datasheet |
| 4U-L12.5 | 13.8 | 12.5 | Lister Petter TR219G1 | 4 | Datasheet |
| 4U-L16 | 18 | 16 | Lister Petter SA423G1 | 4.7 | Datasheet |
| 4U-L21 | 23 | 21 | Lister Petter SA427G1 | 5.8 | Datasheet |
| 4U-L25B | 27.5 | 25 | Lister Petter TR328G1 | 6.7 | Datasheet |
| 4U-L25 | 28 | 25 | Lister Petter SA430G1 | 7.3 | Datasheet |
| 4U-L30 | 33 | 30 | Lister Petter SA432G1 | 8.5 | Datasheet |
| 4U-L40 | 44 | 40 | Lister Petter SA432G2 | 9.7 | Datasheet |
| 4U-L45 | 50 | 45 | Lister Petter TR438G1 | 10.8 | Datasheet |
| 4U-L50 | 55 | 50 | Lister Petter SA435G1 | 12.3 | Datasheet |
| 4U-L50B | 55 | 50 | Lister Petter LP443G1 | 12.9 | Datasheet |
| 4U-L60 | 66 | 60 | Lister Petter SA441G1 | 15.3 | Datasheet |
| 4U-L60B | 66 | 60 | Lister Petter TR441G1 | 15.4 | Datasheet |
| 4U-L63 | 69 | 63 | Lister Petter LP443G2 | 15.1 | Datasheet |
| 4U-L66 | 72 | 66 | Lister Petter SA441G2 | 16.1 | Datasheet |
| 4U-L83 | 90 | 83 | Lister Petter LP443G3 | 19.5 | Datasheet |
| 4U-L100 | 110 | 100 | Lister Petter LP443G4 | 23 | Datasheet |
| 4U-L113 | 125 | 113 | Lister Petter LP443G5 | — | Datasheet |
| 4U-L125 | 138 | 125 | Lister Petter LP443G6 | 28.3 | Datasheet |
| 4U-L125B | 138 | 125 | Lister Petter TR661G2 | 30.7 | Datasheet |
| 4U-L138 | 150 | 138 | Lister Petter LP665G1 | 30.5 | Datasheet |
| 4U-L150 | 165 | 150 | Lister Petter LP665G2 | 33.1 | Datasheet |
| 4U-L188 | 206 | 188 | Lister Petter LP665G3 | 39.7 | Datasheet |
| 4U-L200 | 220 | 200 | Lister Petter LP689G1 | 44.1 | Datasheet |
| 4U-L225 | 248 | 225 | Lister Petter LP689G2 | 49.6 | Datasheet |
| 4U-L250 | 275 | 250 | Lister Petter LP689G3 | 55.1 | Datasheet |
| 4U-L280 | 300 | 280 | Lister Petter LP612G1 | 58.8 | Datasheet |
| 4U-L325 | 358 | 325 | Lister Petter LP612G2 | 66.9 | Datasheet |
| 4U-L350 | 385 | 350 | Lister Petter LP612G3 | 72.9 | Datasheet |
| 4U-L375 | 413 | 375 | Lister Petter LP613G1 | 79 | Datasheet |
| 4U-L400 | 440 | 400 | Lister Petter LP613G2 | 87 | Datasheet |
| 4U-L500 | 545 | 500 | Lister Petter LP625EG1 | 111 | Datasheet |
| 4U-L575 | 630 | 575 | Lister Petter LP625EG2 | 124 | Datasheet |
| 4U-L638 | 695 | 638 | Lister Petter LP625EG3 | 136 | Datasheet |
| 4U-L700 | 765 | 700 | Lister Petter LP625EG4 | 148 | Datasheet |
| 4U-L750 | 820 | 750 | Lister Petter LP625EG5 | 163 | Datasheet |
| 4U-L825 | 900 | 825 | Lister Petter LP625EG7 | — | Datasheet |
| 4U-L900 | 985 | 900 | Lister Petter LP625EG9 | 197.1 | Datasheet |
| 4U-L1000 | 1,095 | 1,000 | Lister Petter LP625EG10 | 212.8 | Datasheet |
Ratings to ISO 8528 at 50 Hz, 1500 rpm.
Straight from the datasheets. For one model in detail open its page from the table above, or build it in 3D.

1-year warranty
Compact Lister Petter-powered sets built for long, low-maintenance running — a proven choice for farms, telecom sites, workshops and remote cabins.
39 models from 11 to 1,095 kVA standby: 11, 13.8, 18, 23, 27.5, 28, 33, 44, 50, 55, 66, 69, 72, 90, 110, 125, 138, 150, 165, 206, 220, 248, 275, 300, 358, 385, 413, 440, 545, 630, 695, 765, 820, 900, 985, 1,095 kVA. Each model has its own datasheet with the engine, alternator, fuel consumption and dimensions.
It depends on the rating and the load. From the datasheets: 4U-L10 (11 kVA) uses about 2.3 L/h at 75% and 2.9 L/h at 100% prime load; 4U-L500 (545 kVA) uses about 85 L/h at 75% and 111 L/h at 100% prime load; 4U-L1000 (1,095 kVA) uses about 158.8 L/h at 75% and 212.8 L/h at 100% prime load. Every model page lists its own figures.
Standby is the rating for mains-failure use; prime is the rating for continuous running with a varying load (ISO 8528). For example, the 4U-L100 is 110 kVA standby and 100 kVA prime. Size on prime if the generator is your main source of power.
Alternator: 4U · Leroy-Somer | Stamford. Controller: Deep Sea DSE4520 MKII / DSE4520 / DSE6110 MKII / DSE6120, depending on the model. The exact frame and controller for each rating are on its datasheet.
12 months / 1,000 running hours from 4U Power Generation, with service contracts available after handover.
Send the kVA or your load list on WhatsApp — a sales engineer replies with options and pricing, usually within the hour.