Automatic transfer switch panels

ATS Panel Supplier in the UAE — Automatic Transfer Switches 63–4000 A

Automatic transfer switch panels that start your generator and take over the load within seconds of a power cut — configured to your generator, earthing system and utility requirements in Sharjah, Dubai, Abu Dhabi, Saudi Arabia and Iraq.

Motorised, contactor & ACB types
63 – 4000 A
Switched neutral where required
3P / 4P
Adjustable timers & cool-down
5–15 s transfer
Indoor or outdoor enclosures
IP54 / IP65

What an ATS panel does

An automatic transfer switch monitors mains voltage and frequency. When supply fails it signals the generator to start, waits for stable output, transfers the load, and returns it to mains once the grid is healthy — then lets the engine cool down before stopping. No one needs to be on site.

ATS panel types we supply

We select the switching technology to suit the rating and duty:

  • Motorised changeover ATS — compact and cost-effective, 63–1600 A
  • Contactor-based ATS — simple and fast for smaller loads
  • ACB changeover panels — 630–4000 A with protection and metering
  • Multi-source logic — mains / generator / generator and bypass options

Sizing an automatic transfer switch

Size the ATS to the generator's full-load current, or the incoming mains breaker if larger. At 400 V three-phase, current ≈ kVA × 1.44: a 250 kVA generator needs a 400 A ATS, a 500 kVA set an 800 A panel. Our kVA calculator recommends the ATS rating automatically.

Built for UAE plant rooms and utility approval

Powder-coated IP54 enclosures (IP65 for outdoor), mechanical and electrical interlocks, clear labelling and function testing before dispatch. Panels can be configured to DEWA, SEWA, ADDC/TAQA or SEC requirements on request.

ATS panel range

Browse products
  • Automatic Transfer Switch Panel 63–400 A
    ATS Panels

    Automatic Transfer Switch Panel 63–400 A

    1-year warranty

    Wall- or floor-mounted ATS panels that switch your load from mains to generator in seconds when power fails — and back again when it returns. Motorised changeover or contactor based, 3- or 4-pole.

  • High-Current ATS Panel 630–4000 A
    ATS Panels

    High-Current ATS Panel 630–4000 A

    1-year warranty

    Floor-standing ATS and ACB-based changeover panels for industrial plants, hospitals and towers — with metering, bypass and multi-source (mains/generator/generator) logic.

kVA Calculator

What size generator do you need?

Enter your load or pick your site type. We add the right safety margin and match you to real units from our catalog.

Generator sizing calculator

Standby, 45 °C, 15 % growth. Open the full calculator for motors, UPS and prime duty.

Minimum standby rating

121 kVA

Best-fit 4U model

4U-L113

Lister Petter · +3

FAQ

Frequently asked questions

Match the ATS current rating to the generator's full-load current (or the incoming mains breaker, whichever is higher). At 400 V three-phase, current ≈ kVA × 1.44 — so a 250 kVA generator needs about 360 A, meaning a 400 A ATS.

4-pole (switched neutral) is recommended when the generator neutral is separately earthed or when earth-fault protection must work correctly on both sources. We confirm this against your earthing system.

Typically 5–15 seconds from mains failure to load on generator, most of which is engine start and stabilisation. Timers are adjustable to avoid nuisance starts on short dips.

News

Related guides

Send your generator details — get the matching ATS

Share the generator kVA (or a nameplate photo) and your main breaker size on WhatsApp. We'll propose the right ATS panel and price the same day.