4U-P350 — 350 kVA prime / 400 kVA standby Perkins diesel generator

350 kVA prime / 400 kVA standby, powered by a Perkins 2206A-E13TAG2 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 350 kVA prime
  • 400 kVA standby
  • Perkins 2206A-E13TAG2
  • 1-year warranty
4U-P350 — 350 kVA prime / 400 kVA standby Perkins diesel generator

Output ratings

Output ratings — 4U-P350
Standby (ESP)400 kVA / 320 kW
Prime (PRP)350 kVA / 280 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-P350
Make / modelPerkins 2206A-E13TAG2
Cylinders6 in-line
Displacement12.5 L
Bore × stroke130 × 157 mm
AspirationTurbocharged, air-to-air charge cooled
GoverningElectronic
CoolingWater cooled, radiator for 50 °C ambient
Coolant capacity51.4 L
Lube oil capacity40 L

Alternator

Alternator — 4U-P350
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A46-H
Stamford frameS4L1D-E41
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-P350
50 % prime load54 L/h
75 % prime load71 L/h
100 % prime load77 L/h
Standby rating80 L/h

Dimensions & weight

Dimensions & weight — 4U-P350
Open set (L × W × H)3080 × 1200 × 1830 mm
Open set weight2,780 kg
Silent canopy (L × W × H)4414 × 1614 × 2235 mm
Canopy weight3,440 kg
Base fuel tank760 L
Noise @ 7 m80 dB(A) ± 3

Control & protection

Control & protection — 4U-P350
ControllerDeep Sea DSE6110 MKII — auto start / AMF
Main breaker3-pole LS MCCB
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-P300B330300Perkins 1706A-E93TAG165Datasheet
4U-P352388352Perkins 1706A-E93TAG277Datasheet
4U-P350400350Perkins 2206A-E13TAG277Datasheet