Skip to content
4U PowerGenerationFZC

Perkins generating set · 50 Hz

4U-P13 — 13 kVA prime / 14 kVA standby Perkins diesel generator

13 kVA prime / 14 kVA standby, powered by a Perkins 403A(D)-15G1 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 13 kVA prime
  • 14 kVA standby
  • Perkins 403A(D)-15G1
  • 1-year warranty
4U-P13 — 13 kVA prime / 14 kVA standby Perkins diesel generator

Output ratings

Output ratings — 4U-P13
Standby (ESP)14 kVA / 11.2 kW
Prime (PRP)13 kVA / 10.4 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-P13
Make / modelPerkins 403A(D)-15G1
Cylinders3 in-line
Displacement1.5 L
Bore × stroke84 × 90 mm
AspirationNaturally aspirated
GoverningMechanical
CoolingWater cooled, radiator for 50 °C ambient
Coolant capacity6 L
Lube oil capacity6 L

Alternator

Alternator — 4U-P13
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A40-C
Stamford frameS0L1P1
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-P13
50 % prime load2 L/h
75 % prime load2.8 L/h
100 % prime load3.7 L/h
Standby rating4.1 L/h

Dimensions & weight

Dimensions & weight — 4U-P13
Open set (L × W × H)1635 × 750 × 1260 mm
Open set weight495 kg
Silent canopy (L × W × H)2152 × 1004 × 1342 mm
Canopy weight765 kg
Base fuel tank169 L
Noise @ 7 m68 dB(A) ± 3

Control & protection

Control & protection — 4U-P13
ControllerDeep Sea DSE4520 MKII — auto start / AMF
Main breaker3-pole LS MCCB
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-P99.99Perkins 403A-11G13Datasheet
4U-P131413Perkins 403A(D)-15G13.7Datasheet
4U-P1516.515Perkins 403A-15G23.7Datasheet
4U-P202220Perkins 404A(D)-22G15.3Datasheet
All 42 Perkins models →
CallWhatsApp