Skip to content
4U PowerGenerationFZC

Lister Petter generating set · 50 Hz

4U-L700 — 700 kVA prime / 765 kVA standby Lister Petter diesel generator

700 kVA prime / 765 kVA standby, powered by a Lister Petter LP625EG4 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 700 kVA prime
  • 765 kVA standby
  • Lister Petter LP625EG4
  • 1-year warranty
4U-L700 — 700 kVA prime / 765 kVA standby Lister Petter diesel generator

Output ratings

Output ratings — 4U-L700
Standby (ESP)765 kVA / 612 kW
Prime (PRP)700 kVA / 560 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-L700
Make / modelLister Petter LP625EG4
Cylinders6 in-line
Displacement25.18 L
Bore × stroke170 × 185 mm
AspirationTurbocharged, air-to-air charge cooled
GoverningElectronic
CoolingWater cooled, radiator for 52 °C ambient
Coolant capacity170 L
Lube oil capacity75 L

Alternator

Alternator — 4U-L700
Make4U · Leroy-Somer | Stamford
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-L700
50 % prime load77 L/h
75 % prime load113 L/h
100 % prime load148 L/h
Standby rating163 L/h

Dimensions & weight

Dimensions & weight — 4U-L700
Open set (L × W × H)4300 × 1750 × 2200 mm
Silent canopy (L × W × H)6000 × 2440 × 2590 mm
Base fuel tank1,170 L

Control & protection

Control & protection — 4U-L700
ControllerDeep Sea DSE6110 MKII — auto start / AMF
Main breaker3-pole LS MCCB
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-L575630575Lister Petter LP625EG2124Datasheet
4U-L638695638Lister Petter LP625EG3136Datasheet
4U-L700765700Lister Petter LP625EG4148Datasheet
4U-L750820750Lister Petter LP625EG5163Datasheet
4U-L825900825Lister Petter LP625EG7—Datasheet
All 39 Lister Petter models →
CallWhatsApp