4U-L200 — 200 kVA prime / 220 kVA standby Lister Petter diesel generator

200 kVA prime / 220 kVA standby, powered by a Lister Petter LP689G1 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 200 kVA prime
  • 220 kVA standby
  • Lister Petter LP689G1
  • 1-year warranty
4U-L200 — 200 kVA prime / 220 kVA standby Lister Petter diesel generator

Output ratings

Output ratings — 4U-L200
Standby (ESP)220 kVA / 176 kW
Prime (PRP)200 kVA / 160 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-L200
Make / modelLister Petter LP689G1
Cylinders6 in-line
Displacement8.82 L
Bore × stroke114 × 144 mm
AspirationTurbocharged, air-to-air charge cooled
GoverningElectronic
CoolingWater cooled, radiator for 52 °C ambient
Coolant capacity49 L
Lube oil capacity19 L

Alternator

Alternator — 4U-L200
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A44-M
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-L200
50 % prime load22.8 L/h
75 % prime load32.8 L/h
100 % prime load44.1 L/h
Standby rating49.6 L/h

Dimensions & weight

Dimensions & weight — 4U-L200
Open set (L × W × H)3015 × 1000 × 1980 mm
Silent canopy (L × W × H)4414 × 1600 × 2250 mm
Base fuel tank760 L

Control & protection

Control & protection — 4U-L200
ControllerDeep Sea DSE6110 MKII — auto start / AMF
Main breaker3-pole LS MCCB
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-L150165150Lister Petter LP665G233.1Datasheet
4U-L188206188Lister Petter LP665G339.7Datasheet
4U-L200220200Lister Petter LP689G144.1Datasheet
4U-L225248225Lister Petter LP689G249.6Datasheet
4U-L250275250Lister Petter LP689G355.1Datasheet
All 39 Lister Petter models →