Skip to content
4U PowerGenerationFZC

Lister Petter generating set · 50 Hz

4U-L30 — 30 kVA prime / 33 kVA standby Lister Petter diesel generator

30 kVA prime / 33 kVA standby, powered by a Lister Petter SA432G1 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 30 kVA prime
  • 33 kVA standby
  • Lister Petter SA432G1
  • 1-year warranty
4U-L30 — 30 kVA prime / 33 kVA standby Lister Petter diesel generator

Output ratings

Output ratings — 4U-L30
Standby (ESP)33 kVA / 26.4 kW
Prime (PRP)30 kVA / 24 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-L30
Make / modelLister Petter SA432G1
Cylinders4 in-line
Displacement3.17 L
Bore × stroke98 × 105 mm
AspirationNaturally aspirated
GoverningElectronic
CoolingWater cooled, radiator for 52 °C ambient
Coolant capacity11.4 L
Lube oil capacity8 L

Alternator

Alternator — 4U-L30
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A42-C
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-L30
50 % prime load4.4 L/h
75 % prime load6.2 L/h
100 % prime load8.5 L/h
Standby rating9.4 L/h

Dimensions & weight

Dimensions & weight — 4U-L30
Open set (L × W × H)1900 × 750 × 1400 mm
Silent canopy (L × W × H)2307 × 1044 × 1415 mm
Base fuel tank198 L

Control & protection

Control & protection — 4U-L30
ControllerDeep Sea DSE4520 MKII — auto start / AMF
Main breaker3-pole LS MCCB
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-L25B27.525Lister Petter TR328G16.7Datasheet
4U-L252825Lister Petter SA430G17.3Datasheet
4U-L303330Lister Petter SA432G18.5Datasheet
4U-L404440Lister Petter SA432G29.7Datasheet
4U-L455045Lister Petter TR438G110.8Datasheet
All 39 Lister Petter models →