Skip to content
4U PowerGenerationFZC

Lister Petter generating set · 50 Hz

4U-L16 — 16 kVA prime / 18 kVA standby Lister Petter diesel generator

16 kVA prime / 18 kVA standby, powered by a Lister Petter SA423G1 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 16 kVA prime
  • 18 kVA standby
  • Lister Petter SA423G1
  • 1-year warranty
4U-L16 — 16 kVA prime / 18 kVA standby Lister Petter diesel generator

Output ratings

Output ratings — 4U-L16
Standby (ESP)18 kVA / 14 kW
Prime (PRP)16 kVA / 13 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-L16
Make / modelLister Petter SA423G1
Cylinders4 in-line
Displacement2.27 L
Bore × stroke85 × 100 mm
AspirationNaturally aspirated
GoverningElectronic
CoolingWater cooled, radiator for 52 °C ambient
Coolant capacity9.1 L
Lube oil capacity8 L

Alternator

Alternator — 4U-L16
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A40-E
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-L16
50 % prime load2.6 L/h
75 % prime load3.7 L/h
100 % prime load4.7 L/h
Standby rating5.2 L/h

Dimensions & weight

Dimensions & weight — 4U-L16
Open set (L × W × H)1500 × 700 × 1240 mm
Silent canopy (L × W × H)1800 × 910 × 1300 mm
Base fuel tank90 L

Control & protection

Control & protection — 4U-L16
ControllerDeep Sea DSE4520 MKII — auto start / AMF
Main breaker3-pole LS Electric
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-L101110Lister Petter SA315G22.9Datasheet
4U-L12.513.812.5Lister Petter TR219G14Datasheet
4U-L161816Lister Petter SA423G14.7Datasheet
4U-L212321Lister Petter SA427G15.8Datasheet
4U-L25B27.525Lister Petter TR328G16.7Datasheet
All 39 Lister Petter models →