Skip to content
4U PowerGenerationFZC

Cummins generating set · 50 Hz

4U-C298 — 298 kVA prime / 330 kVA standby Cummins diesel generator

298 kVA prime / 330 kVA standby, powered by a Cummins QSL9-G5 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 298 kVA prime
  • 330 kVA standby
  • Cummins QSL9-G5
  • 1-year warranty
4U-C298 — 298 kVA prime / 330 kVA standby Cummins diesel generator

Output ratings

Output ratings — 4U-C298
Standby (ESP)330 kVA / 264 kW
Prime (PRP)298 kVA / 238.4 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-C298
Make / modelCummins QSL9-G5
Cylinders6 in-line
Displacement8.9 L
Bore × stroke114 × 145 mm
AspirationTurbocharged, air-to-air charge cooled
GoverningElectronic
CoolingWater cooled, radiator for 50 °C ambient
Coolant capacity36 L
Lube oil capacity26.5 L

Alternator

Alternator — 4U-C298
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A46-F
Stamford frameHCI444D/S4L1D-E41
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-C298
50 % prime load31 L/h
75 % prime load46 L/h
100 % prime load63 L/h
Standby rating75 L/h

Dimensions & weight

Dimensions & weight — 4U-C298
Open set (L × W × H)2850 × 1420 × 2130 mm
Open set weight2,650 kg
Silent canopy (L × W × H)5205 × 1625 × 2620 mm
Canopy weight4,000 kg
Base fuel tank625 L
Noise @ 7 m83 dB(A) ± 3

Control & protection

Control & protection — 4U-C298
ControllerDeep Sea DSE6120 — auto start / AMF
Main breaker3-pole LS MCCB
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-C250B275250Cummins QSL9-G359Datasheet
4U-C271302271Cummins 6LTAA9.5-G356Datasheet
4U-C298330298Cummins QSL9-G563Datasheet
4U-C300330300Cummins 6LTAA9.5-G170Datasheet
4U-C365400365Cummins QSG12-G372Datasheet
All 44 Cummins models →
CallWhatsApp