4U-C2290 — 2,290 kVA prime / 2,508 kVA standby Cummins diesel generator

2290 kVA prime / 2508 kVA standby, powered by a Cummins QSK60-G6 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 2290 kVA prime
  • 2508 kVA standby
  • Cummins QSK60-G6
  • 1-year warranty
4U-C2290 — 2,290 kVA prime / 2,508 kVA standby Cummins diesel generator

Output ratings

Output ratings — 4U-C2290
Standby (ESP)2,508 kVA / 2,006 kW
Prime (PRP)2,290 kVA / 1,832 kW
Voltage / frequency480/277 V · 3-phase · 60 Hz · 1800 rpm (60 Hz build only)
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-C2290
Make / modelCummins QSK60-G6
Cylinders16 in 60° V
Displacement60.2 L
Bore × stroke159 × 190 mm
AspirationTurbocharged, water charge cooled
GoverningElectronic
CoolingWater cooled, radiator for 50 °C ambient
Coolant capacity490 L
Lube oil capacity261 L

Alternator

Alternator — 4U-C2290
Make4U · Leroy-Somer | Stamford
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-C2290
50 % prime load247 L/h
75 % prime load356 L/h
100 % prime load466 L/h
Standby rating521 L/h

Dimensions & weight

Dimensions & weight — 4U-C2290
Base fuel tankOn request

Control & protection

Control & protection — 4U-C2290
ControllerDeep Sea (model on request)
Main breakerOn request
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-C16081,9131,608Cummins KTA50-G9330Datasheet
4U-C20472,2502,047Cummins QSK60-G4394Datasheet
4U-C22902,5082,290Cummins QSK60-G6466Datasheet
All 44 Cummins models →
CallWhatsApp