4U-C640 — 640 kVA prime / 681 kVA standby Cummins diesel generator

640 kVA prime / 681 kVA standby, powered by a Cummins VTA28-G5 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 640 kVA prime
  • 681 kVA standby
  • Cummins VTA28-G5
  • 1-year warranty
4U-C640 — 640 kVA prime / 681 kVA standby Cummins diesel generator

Output ratings

Output ratings — 4U-C640
Standby (ESP)681 kVA / 545 kW
Prime (PRP)640 kVA / 512 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-C640
Make / modelCummins VTA28-G5
Cylinders12 in 60° V
Displacement28 L
Bore × stroke140 × 152 mm
AspirationTurbocharged & aftercooled
GoverningElectronic
CoolingWater cooled, radiator for 50 °C ambient
Coolant capacity83 L
Lube oil capacity83 L

Alternator

Alternator — 4U-C640
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A473-F
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-C640
Fuel consumptionOn request

Dimensions & weight

Dimensions & weight — 4U-C640
Open set (L × W × H)3910 × 2010 × 2705 mm
Open set weight6,480 kg
Silent canopy (L × W × H)5873 × 2224 × 2817.8 mm
Canopy weight8,815 kg
Base fuel tank1,835 L
Noise @ 7 m85 dB(A) ± 3

Control & protection

Control & protection — 4U-C640
ControllerDeep Sea DSE6120 — auto start / AMF
Main breaker3-pole LS MCCB
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-C500C550500Cummins KTA19-G4107Datasheet
4U-C500D550500Cummins QSX15-G8107Datasheet
4U-C640681640Cummins VTA28-G5—Datasheet
4U-C652715652Cummins QSK19-G4147Datasheet
4U-C750825750Cummins VTA28-G6195Datasheet
All 44 Cummins models →
CallWhatsApp