Skip to content
4U PowerGenerationFZC

Cummins generating set · 50 Hz

4U-C500B — 500 kVA prime / 550 kVA standby Cummins diesel generator

500 kVA prime / 550 kVA standby, powered by a Cummins QSZ13-G3 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 500 kVA prime
  • 550 kVA standby
  • Cummins QSZ13-G3
  • 1-year warranty
4U-C500B — 500 kVA prime / 550 kVA standby Cummins diesel generator

Output ratings

Output ratings — 4U-C500B
Standby (ESP)550 kVA / 440 kW
Prime (PRP)500 kVA / 400 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-C500B
Make / modelCummins QSZ13-G3
Cylinders6 in-line
Displacement13 L
Bore × stroke130 × 163 mm
AspirationTurbocharged, air-to-air charge cooled
GoverningElectronic
CoolingWater cooled, radiator for 50 °C ambient
Coolant capacity62 L
Lube oil capacity78 L

Alternator

Alternator — 4U-C500B
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A473-C
Stamford frameHCI544D/S5L1D-C41
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-C500B
50 % prime load48.9 L/h
75 % prime load74.2 L/h
100 % prime load101 L/h
Standby rating105.5 L/h

Dimensions & weight

Dimensions & weight — 4U-C500B
Open set (L × W × H)3505 × 2005 × 2310 mm
Open set weight3,500 kg
Silent canopy (L × W × H)5205 × 1625 × 2620 mm
Canopy weight4,950 kg
Base fuel tank1,039 L
Noise @ 7 m86.2 dB(A) ± 3

Control & protection

Control & protection — 4U-C500B
ControllerDeep Sea DSE6120 — auto start / AMF
Main breaker3-pole LS MCCB
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-C455500455Cummins QSZ13-G593Datasheet
4U-C500512500Cummins M15-G8107Datasheet
4U-C500B550500Cummins QSZ13-G3101Datasheet
4U-C500C550500Cummins KTA19-G4107Datasheet
4U-C500D550500Cummins QSX15-G8107Datasheet
All 44 Cummins models →