4U-B600 — 600 kVA prime / 660 kVA standby Baudouin diesel generator

600 kVA prime / 660 kVA standby, powered by a Baudouin 6M33G660/5 engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 600 kVA prime
  • 660 kVA standby
  • Baudouin 6M33G660/5
  • 1-year warranty
4U-B600 — 600 kVA prime / 660 kVA standby Baudouin diesel generator

Output ratings

Output ratings — 4U-B600
Standby (ESP)660 kVA / 528 kW
Prime (PRP)600 kVA / 480 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-B600
Make / modelBaudouin 6M33G660/5
Cylinders6 in-line
Displacement19.6 L
Bore × stroke150 × 185 mm
AspirationTurbocharged & aftercooled
GoverningElectronic
CoolingWater cooled, radiator for 50 °C ambient
Lube oil capacity64 L

Alternator

Alternator — 4U-B600
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A473-E
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-B600
50 % prime load61.7 L/h
75 % prime load91.4 L/h
100 % prime load122.7 L/h
Standby rating136.3 L/h

Dimensions & weight

Dimensions & weight — 4U-B600
Open set (L × W × H)3700 × 1536 × 2230 mm
Open set weight4,400 kg
Silent canopy (L × W × H)4850 × 1800 × 2660 mm
Canopy weight6,000 kg
Base fuel tank1,150 L
Noise @ 7 m92 dB(A) ± 3

Control & protection

Control & protection — 4U-B600
ControllerDeep Sea DSE6120 MKII — auto start / AMF
Main breaker3-pole LS Electric
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-B450500450Baudouin 6M21G500/5—Datasheet
4U-B500550500Baudouin 6M21G8D0/S—Datasheet
4U-B600660600Baudouin 6M33G660/5122.7Datasheet
4U-B650715650Baudouin 6M33G710/5—Datasheet
4U-B650B715650Baudouin 6M33G1D0/S—Datasheet
All 26 Baudouin models →
CallWhatsApp