Skip to content
4U PowerGenerationFZC

Baudouin generating set · 50 Hz

4U-B200 — 200 kVA prime / 220 kVA standby Baudouin diesel generator

200 kVA prime / 220 kVA standby, powered by a Baudouin 6M16G2D0/S engine with a Leroy-Somer or Stamford alternator and Deep Sea controller. Supplied open or in a silent canopy, with delivery, installation and commissioning across the UAE.

  • 200 kVA prime
  • 220 kVA standby
  • Baudouin 6M16G2D0/S
  • 1-year warranty
4U-B200 — 200 kVA prime / 220 kVA standby Baudouin diesel generator

Output ratings

Output ratings — 4U-B200
Standby (ESP)220 kVA / 176 kW
Prime (PRP)200 kVA / 160 kW
Voltage / frequency400/230 V · 3-phase · 50 Hz · 1500 rpm
Power factor0.8
Other voltages380/220 · 415/240 · 440/254 · 480/277 V

Engine

Engine — 4U-B200
Make / modelBaudouin 6M16G2D0/S
Cylinders6 in-line
Displacement9.7 L
Bore × stroke126 × 130 mm
AspirationTurbocharged & aftercooled
GoverningElectronic
CoolingWater cooled, radiator for 50 °C ambient
Coolant capacity42 L
Lube oil capacity30 L

Alternator

Alternator — 4U-B200
Make4U · Leroy-Somer | Stamford
Leroy-Somer frameTAL-A44-M
TypeSelf-excited, 4-pole, single bearing
Insulation / protectionClass H · IP23
Voltage regulation± 1 %

Fuel consumption

Fuel consumption — 4U-B200
50 % prime load22.4 L/h
75 % prime load32.4 L/h
100 % prime load43.1 L/h
Standby rating46.9 L/h

Dimensions & weight

Dimensions & weight — 4U-B200
Open set (L × W × H)2500 × 1050 × 1660 mm
Open set weight2,250 kg
Silent canopy (L × W × H)3300 × 1200 × 1970 mm
Canopy weight3,050 kg
Base fuel tank380 L
Noise @ 7 m84 dB(A) ± 3

Control & protection

Control & protection — 4U-B200
ControllerDeep Sea DSE6120 MKII — auto start / AMF
Main breaker3-pole LS Electric
Shutdowns & alarmsOver/under speed & voltage, over-current, low oil pressure, high engine temperature, battery, start/stop failure, emergency stop
Warranty12 months or 1,000 running hours, whichever first
  • Prime (PRP): unlimited hours at an average 80 % load over each 24 h, with 10 % overload for 1 h in every 12 h.
  • Standby (ESP): up to 500 h a year at an average 80 % load during mains failure; no overload.
  • Options: silent canopy or container, external tank (500–5,000 L), ATS panel, synchronising, 55 °C radiator, engine heaters.

Request this spec

Typical reply: within 1 working hour on WhatsApp

By sending this form you agree to our privacy policy.

Nearby models

4U generator models
ModelStandby kVAPrime kVAEngineFuel 100% (L/h)Datasheet
4U-B130143130Baudouin 6M11G2D0/S30.2Datasheet
4U-B150165150Baudouin 6M11G4D0/S32.6Datasheet
4U-B200220200Baudouin 6M16G2D0/S43.1Datasheet
4U-B230250230Baudouin 6M16G4D0/S50.9Datasheet
4U-B250275250Baudouin 6M16G6D0/S—Datasheet
All 26 Baudouin models →
CallWhatsApp