10 kVA generator · UAE, KSA & Iraq
A 10 kVA generator delivers about 8 kW at 0.8 power factor — the right size for villas, shops, small offices, telecom shelters and site cabins. We supply it with Kubota, Perkins or Lister Petter engines from our Sharjah warehouse, with a matched ATS panel and a 1-year warranty.
| Standby rating | 10 kVA / 8 kW |
|---|---|
| Prime rating (typical) | ≈ 9 kVA |
| Full-load current @ 400 V | 14 A |
| Matching ATS panel | 63 A, 4-pole |
| Fuel use @ 50 / 75 / 100 % load | 1.1 / 1.6 / 2.2 L/h |
| Base tank for 8 h @ 75 % | ≈ 15 L |
| Engine options | Kubota, Perkins, Lister Petter |
| Enclosure | Sound-attenuated canopy |
| Voltage / frequency | 400/230 V, 50 Hz (60 Hz for KSA on request) |
| Warranty | 12 months |
Approximate values at 0.8 pf and 400 V; final figures are confirmed for the chosen engine model in your quotation.
A 10 kVA set typically powers villas, shops, small offices, telecom shelters and site cabins.
At this size a silent canopy and single- or three-phase output are the usual choices; Kubota and Perkins 400 Series engines keep noise and fuel low.
Size my generator →Open a model for full specifications and its downloadable datasheet.
From the catalog

1-year warranty
Ultra-quiet Kubota-powered sets for villas, clinics, retail units and events where noise matters. Compact footprint, single or three-phase output.

1-year warranty
Compact Lister Petter-powered sets built for long, low-maintenance running — a proven choice for farms, telecom sites, workshops and remote cabins.

1-year warranty
Compact Perkins 400 and 1100 Series powered generator sets for villas, shops, telecom sites and light commercial standby. Low fuel consumption, wide parts availability across the GCC and fast delivery from our SAIF Zone warehouse.
10 kVA generator
About 8 kW of running load at 0.8 power factor. Keep 20–25 % headroom for motor starting and Gulf heat — in practice roughly 6 kW continuous, for example around 2 split AC units of 2 tons, or the equivalent mix of lighting, pumps and equipment.
Roughly 1.1 L/h at 50 % load, 1.6 L/h at 75 % and 2.2 L/h at full load. Exact figures depend on the engine model; we include the manufacturer's fuel curve with every quotation.
Full-load current at 400 V three-phase is about 14 A, so a 63 A ATS is the usual match — or the main incoming breaker rating if that is larger. A 4-pole ATS is recommended where the generator neutral is separately earthed.
It depends on the engine brand, enclosure, controller and whether you need an ATS and fuel tank. Send us the site and delivery city on WhatsApp and we reply the same working day with 2–3 engine options side by side.
Standby (10 kVA) is for emergency backup with limited annual hours. If the set is your main power — a construction site or an area with daily outages — size on the prime rating (about 9 kVA for this set) or choose the next size up.
Send the delivery city and duty (standby or prime) — we reply with engine options, price and lead time.